Original Research ArticleInternational Journal of Pharmaceutical InvestigationVol. 3 | Issue 4 | pp. 225–233Open access
Evaluation of in vivo efficacy and toxicity of prednisolone- loaded hydrogel-based drug delivery device
- 1*,
- 1,
- 1,
- 1
- 1 Department of Chemical Technology, Division of Pharmaceutical and Fine Chemical Technology, University College of Science and Technology, University of Calcutta, Kolkata, West Bengal, INDIA.
Published in International Journal of Pharmaceutical Investigation
Correspondence: Amit Kumar De
Department of Chemical Technology, Division of Pharmaceutical and Fine Chemical Technology, University College of Science and Technology, University of Calcutta, Kolkata, West Bengal, INDIA.
Email: amitkumarde200401@gmail.com
- DOI:
- 10.4103/2230-973X.121308
How to cite
De, A. K., Bhattacharya, P., Datta, S., & Mukherjee, A. Evaluation of in vivo efficacy and toxicity of prednisolone- loaded hydrogel-based drug delivery device. International Journal of Pharmaceutical Investigation, 3(4), 225–233. https://doi.org/10.4103/2230-973X.121308
Abstract
Drugs prescribed for the treatment of moderate to severe inflammatory bowel disease (IBD) are associated with number of side effects. Targeted drug delivery is essential for the treatment of inflammatory bowel disease in order to increase efficacy and reduce toxicity. The established delivery system is designed on enzyme and time-based release of poorly soluble prednisolone, a drug of choice for the treatment of moderate to severe inflammatory bowel disease. Their pharmacological evaluation was done in 2,4,6-trinitrobenzene sulphonic acid (TNBS)-induced model of colitis in rat. The drug was administered once daily for 3 consecutive days. Visible severity of colitis, tissue to bodyweight ratio, tissue histology along with nitric oxide (NO), malondialdehyde (MDA) and myeloperoxidase (MPO) activity of colonic tissue were studied to estimate the efficacy of the drug-loaded delivery system. The highest efficacy was observed for formulation in which Eudragit RS100 (EU) was used along with guar gum (GG) in a ratio 2:5 for the preparation of delivery device. An effective recovery was observed from the study of tissue histology of animals treated with the drug-loaded optimized formulation and the biochemical parameters supported it. The toxicity of prednisolone (PD) was reduced significantly as predicted from thymus to body weight ratio of treated animals. GG and EU RS100 provided a newer bipolymer combination for the colon-targeted delivery of PD which increased its efficacy and reduced the toxic side effects. The in vivo experiments presented effective amelioration from colitis in TNBS-induced animal model of colitis.
Keywords
Subject
Article metadata
| Title | Evaluation of in vivo efficacy and toxicity of prednisolone- loaded hydrogel-based drug delivery device |
|---|---|
| Authors | Amit Kumar De; Plaban Bhattacharya; Sriparna Datta; Arup Mukherjee |
| Affiliations | Department of Chemical Technology, Division of Pharmaceutical and Fine Chemical Technology, University College of Science and Technology, University of Calcutta, Kolkata, West Bengal, INDIA. |
| Corresponding author | amitkumarde200401@gmail.com |
| Journal | International Journal of Pharmaceutical Investigation |
| Volume / Issue | Vol. 3, Issue 4 |
Also in this issue
- Cavamax W7 composite psoralen ethosomal gel versus cavamax W7 psoralen solid complex gel for topical delivery: A comparative evaluationpp. 171–182
- Formulation, characterization, in vitro, in vivo, and histopathological evaluation of transdermal drug delivery containing norfloxacin and Curcuma longapp. 183–187
- Teucrium polium L. extract adsorbed on zinc oxide nanoparticles as a fortified sunscreenpp. 188–193
- Zinc cross-linked hydroxamated alginates for pulsed drug releasepp. 194–202
- Formulation and evaluation of sustained release enteric-coated pellets of budesonide for intestinal deliverypp. 203–211