Original ArticleIndian Journal of Pharmaceutical Education and ResearchVol. 56 | Issue 2 | 2022 | pp. 539–545Open access
Determination of Nitazoxanide in Biological Matrices by LC-MS/MS Technique: Method Development and Validation
- 1*,
- 2
- 1 Department of Pharmaceutical Analysis and Quality Assurance, Nizam Institute of Pharmacy, Hyderabad, Telangana, INDIA.
- 2 Department of Pharmaceutics (Drug Delivery Systems), Annamalai University, Chidambaram, Tamil Nadu, INDIA.
Published in Indian Journal of Pharmaceutical Education and Research
Correspondence: Abdul Saleem Mohammad
Department of Pharmaceutical Analysis and Quality Assurance, Nizam Institute of Pharmacy, Hyderabad, Telangana, INDIA.
Email: abdulsaleemmohammad89@gmail.com
Copyright: © 2022 Manuscript Technomedia. This is an open access article.
- Published:
- Jan 1, 2022
- Received:
- Nov 26, 2020
- Accepted:
- Jan 28, 2022
- DOI:
- 10.5530/ijper.56.2.76
How to cite
Mohammad, A. S., & Jayanthi, B. (2022). Determination of Nitazoxanide in Biological Matrices by LC-MS/MS Technique: Method Development and Validation. Indian Journal of Pharmaceutical Education and Research, 56(2), 539–545. https://doi.org/10.5530/ijper.56.2.76
Abstract
Background: Determination of pharmaceuticals in the biological matrices is essential for toxicologic and pharmacokinetic applications. The main objective of the current work was to develop a bioanalytical method for quantifying nitazoxanide in biological samples by LC-MS/MS. Materials and Methods: Chromatographic elution of nitazoxanide and linagliptin were achieved on C18-hypersil (5 μ, 50x4.6mm) stationary phase with mobile phase consisting of acetonitrile and 0.1% HCOOH (75:15, v/v) processed at 0.8 ml/min flow rate. Linagliptin was utilized as an internal standard (IS). Results: The method was linear in the concentration levels of 0.53–21.2 ng/ml with more than 0.999 r2 values, consisting of 0.53 ng/ml as the lower limit of quantification (LLOQ). Analytes were subjected to pretreatment by liquid-liquid extraction (LLE) procedure with average extraction recovery findings within 99.93±5.04%. Method accuracy findings were present in between 96.44% to 104.31%, and the assessed percentage relative standard deviation findings for within and between run precision were ≤ 4.68%. Conclusion: The developed LC-MS/MS procedure for quantitating nitazoxanide in the biological matrix was suitable for routine analysis of patients’ blood samples for pharmacokinetic studies and drug monitoring.
Keywords
Subject
Article metadata
| Title | Determination of Nitazoxanide in Biological Matrices by LC-MS/MS Technique: Method Development and Validation |
|---|---|
| Authors | Abdul Saleem Mohammad; B Jayanthi |
| Affiliations | Department of Pharmaceutical Analysis and Quality Assurance, Nizam Institute of Pharmacy, Hyderabad, Telangana, INDIA.; Department of Pharmaceutics (Drug Delivery Systems), Annamalai University, Chidambaram, Tamil Nadu, INDIA. |
| Corresponding author | abdulsaleemmohammad89@gmail.com |
| Journal | Indian Journal of Pharmaceutical Education and Research |
| Volume / Issue | Vol. 56, Issue 2 (2022) |
Also in this issue
- Aromatase Inhibitors: Development and Current Perspectives
- Temporal Unpredictability and Probabilistic Uncertainty Induced Anxiety in the Times of COVID-19 Pandemicpp. 321–328
- Perspectives of Presynaptic Autoreceptors and Presynaptic Heteroreceptors in the Mechanism of Neurotransmissionpp. 329–346
- A Brief Review on Solubility Enhancement Technique: Hydrotropypp. 347–355