Original ArticleIndian Journal of Pharmaceutical Education and ResearchVol. 60 | Issue 2s | pp. s522–s532Open access
Development of an RP-HPLC Method for Simultaneous Estimation of Remogliflozin, Metformin and Teneligliptin in Tablet Formulation
- 1*,
- 2,
- 2,
- 2,
- 1,
- 1
- 1 Department of Quality Assurance and Pharmacognosy, Faculty of Pharmacy, Parul College of Pharmacy and Research, Parul University, Bopal, Ahmedabad, Gujarat, INDIA.
- 2 Department of Quality Assurance and Pharma Chemistry, Faculty of Pharmacy, Nootan Pharmacy College, Sankalchand Patel University, Visnagar, Gujarat, INDIA.
Published in Indian Journal of Pharmaceutical Education and Research
Correspondence: Dhwani Shah
Department of Quality Assurance and Pharmacognosy, Faculty of Pharmacy, Parul College of Pharmacy and Research, Parul University, Bopal, Ahmedabad, Gujarat, INDIA.
Email: shahdhwani57@gmail.com
- Received:
- May 28, 2025
- Accepted:
- Sep 15, 2025
- DOI:
- 10.5530/ijper.20260472
How to cite
Shah, D., Patel, S., Shah, U., Patel, K., Vegad, K., & Shah, H. Development of an RP-HPLC Method for Simultaneous Estimation of Remogliflozin, Metformin and Teneligliptin in Tablet Formulation. Indian Journal of Pharmaceutical Education and Research, 60(2s), s522–s532. https://doi.org/10.5530/ijper.20260472
Abstract
Objectives: A cost-effective and reliable RP-HPLC method was developed and validated for the simultaneous estimation of Remogliflozin, Metformin and Teneligliptin in Pharmaceutical dosage form. Materials and Methods: Using an ECO-C18 (15 mm*4.6 mm*5 μ (particle size)) column with a mobile phase consisting of 0.6 M Phosphate Buffer pH 3.5: ACN (Acetonitrile) 40:60 v/v, analysis was conducted at 222 nm with a flow rate of 1.0 mL/min. Results: The validation method followed ICH guidelines, demonstrating linearity with LOQ values of 4.79 µg/mL for Remogliflozin, 24.85 µg/mL for Metformin and 0.56 µg/mL for Teneligliptin. LOD values were determined as 1.43 µg/mL for Remogliflozin, 7.53 µg/mL for Metformin and 0.17 µg/mL for Teneligliptin, with correlation coefficients of 0.99 for all compounds. % Recovery ranged from 99.73% to 100.86% for Remogliflozin, 98.59% to 100.90% for Metformin and 100.11 to 100.89% for Teneligliptin, while relative standard deviation values for Replication, inter-intraday precision were all below 2%. Conclusion: The proposed method exhibited specificity, sensitivity, precision, accuracy, and robustness, making it suitable for routine analysis.
Keywords
Subject
Article metadata
| Title | Development of an RP-HPLC Method for Simultaneous Estimation of Remogliflozin, Metformin and Teneligliptin in Tablet Formulation |
|---|---|
| Authors | Dhwani Shah; Sejalben Patel; Ujashkumar Shah; Khooshbu Patel; Kunjal Vegad; Hirak Shah |
| Affiliations | Department of Quality Assurance and Pharmacognosy, Faculty of Pharmacy, Parul College of Pharmacy and Research, Parul University, Bopal, Ahmedabad, Gujarat, INDIA.; Department of Quality Assurance and Pharma Chemistry, Faculty of Pharmacy, Nootan Pharmacy College, Sankalchand Patel University, Visnagar, Gujarat, INDIA. |
| Corresponding author | shahdhwani57@gmail.com |
| Journal | Indian Journal of Pharmaceutical Education and Research |
| Volume / Issue | Vol. 60, Issue 2s |
Also in this issue
- Artificial Intelligence/Machine Learning in Pharma Analysis and Quality Control: A Real-World Upgradepp. s375–s384
- Emerging Dynamics of the Medical Devices Sector in Indiapp. s385–s410
- Herbal Medicine in Gynecological and Obstetric Care: A Comprehensive Review of Clinical Trialspp. s411–s429
- Quality by Design (QbD) Approach in the Formulation of Liposomal Gel: A Reviewpp. s430–s435
- Fabrication of Microneedle Patches of Indomethacin Using 3DP Technologypp. s436–s442