Original ArticleIndian Journal of Pharmaceutical Education and ResearchVol. 57 | Issue 3 | 2023 | pp. 883–889Open access
LC-MS/MS Analytical Method Development and Validation for Determining Vinamidinium HexafluoroPhosphate Impurity in Etoricoxib
- 1,
- 1*,
- 2,
- 1
- 1 Department of Chemistry, Andhra University, Visakhapatnam, Andhra Pradesh, INDIA.
- 2 Department of Quality Control, Aurobindo Pharma Limited, Hyderabad, Telangana, INDIA.
Published in Indian Journal of Pharmaceutical Education and Research
Correspondence: T Siva Rao
Department of Chemistry, Andhra University, Visakhapatnam, Andhra Pradesh, INDIA.
Email: sivaraoau@gmail.com
Copyright: © 2023 Manuscript Technomedia. This is an open access article.
- Published:
- Jan 1, 2023
- Received:
- Dec 15, 2022
- Accepted:
- Apr 16, 2023
- DOI:
- 10.5530/ijper.57.3.106
How to cite
Ganta, S., Rao, T. S., Srinivas, K. R., & Suman, P. (2023). LC-MS/MS Analytical Method Development and Validation for Determining Vinamidinium HexafluoroPhosphate Impurity in Etoricoxib. Indian Journal of Pharmaceutical Education and Research, 57(3), 883–889. https://doi.org/10.5530/ijper.57.3.106
Abstract
Background and Aim: Process impurities may adversely affect the efficacy, excellent quality, and safety of pharmaceutical drugs. Ultimately, the purpose of this research work was to develop and validate a LC-MS/MS-based method for determining the Vinamidinium hexafluorophosphate impurity (VHP) in Etoricoxib in a simple, specific, accurate, and precise manner. Materials and Methods: To elute the Vinamidinium hexafluorophosphate impurity in Etoricoxib at a flow rate of 0.5mL/min within 20.0 min of runtime, a Symmetry Shield RP18, 5µm column with a 150 x 3.9 mm internal diameter was utilized in binary gradient mode. The buffer solution, which contained formic acid (0.1%) and acetonitrile (100%), as well as a diluent solution of acetonitrile (50%) and water (50%), was used to achieve the chromatographic separation. A triple quadrupole mass spectrometer (Shimadzu LC/MS/MS 8040) in Multiple Reaction Monitoring (MRM) mode was needed to monitor the results. Results and Discussion: The method's linearity was evaluated at levels from 25% to 150%, and the R2 value was discovered to be 0.99. Sensitivity values of 0.04µg/g (LOD) and 0.13µg/g (LOQ) were established. The recovery of impurity levels of Vinamidinium hexafluorophosphate ranges from 70.0% to 130%. Linearity, specificity, accuracy, LOD, LOQ, and precision of the method were all validated. Within the assay variability limitations, it was found that the intra- and inter-day precision values were 0.67%, and 0.58%, respectively. Conclusion: According to ICH and FDA specifications, the optimized method was validated. The developed method was found to be appropriate for quantifying Vinamidinium hexafluorophosphate in Etoricoxib by employing LC-MS.
Keywords
Article metadata
| Title | LC-MS/MS Analytical Method Development and Validation for Determining Vinamidinium HexafluoroPhosphate Impurity in Etoricoxib |
|---|---|
| Authors | Satish Ganta; T Siva Rao; K Rama Srinivas; Pallapati Suman |
| Affiliations | Department of Chemistry, Andhra University, Visakhapatnam, Andhra Pradesh, INDIA.; Department of Quality Control, Aurobindo Pharma Limited, Hyderabad, Telangana, INDIA. |
| Corresponding author | sivaraoau@gmail.com |
| Journal | Indian Journal of Pharmaceutical Education and Research |
| Volume / Issue | Vol. 57, Issue 3 (2023) |
Also in this issue
- Nanosizing Approaches: Current Trends in the Solubility Enhancement of Poorly Water-soluble Drugspp. 625–639
- Inhalable Microparticulate System for Tuberculosis: An Updated Reviewpp. 640–647
- Advances in in vivo Non-invasive Delivery of Gentamicinpp. 648–657
- Emerging Applications of Electrospun Nanofibers Using Various Fabrication Techniquespp. 658–668
- Mentorship in Pharmacy Schools: Students’ Perspectivepp. 669–677